II 08 Peripheral IV Placement

II08_tocConfig.jpg

Chapter Authors & Contributors


8.1 Introduction

Highlights

  • Ultrasound has been shown to increase the success rate of IV placement for difficult access patients.
  • Ultrasound guidance can be used for adults and children.
  • This skill can be learned by physicians, nurses, and technicians.

Peripheral intravenous (IV) catheterization is an invaluable tool in the management of emergency department patients. For patients who require prompt intravenous medications, airway management, or fluid resuscitation, establishing immediate IV access is of paramount importance in initial stabilization. For the majority of emergency department patients, IV access is obtained easily by blind, landmark-guided technique. However, in at least 10% of patients, including those with a history of obesity, edema, IV drug use, dialysis, sickle cell anemia, or other chronic illness requiring frequent IV placement, blind technique fails.[1][2] The use of ultrasound (US) can facilitate rapid peripheral IV access in difficult situations, while avoiding the time and risk associated with central venous catheterization or the discomfort of intra-osseous infusion.[3][4][5]

Ultrasound-guided IV placement has been shown to be safe, rapid, and patient-friendly in both adults and children.[3:1][6][7] It has been shown to be superior to both blind peripheral and blind external jugular vein cannulation.[3:2][8] Physicians, nurses, and ED technicians have all demonstrated the ability to easily learn the procedure.[^1,4,9] Tremendous evidence exists supporting the use of US for vascular access. It is now standard of care to use ultrasound for the placement of central venous catheters.[9]

8.2 Supplies and Preparation

Highlights

-A longer IV catheter is necessary to maximize potential for success.
-Scan the area of interest to find the best target, which will be the vein that is the largest and most superficial.
-Position the patient and the machine for optimal ergonomics.
-The transverse or longitudinal approach may be used.

Supplies & Equipment

Image 8.1 Supplies

II08_Supplies.jpg400

Anatomic Considerations

Similar to landmark-guided peripheral IV insertion, the US-guided technique begins with the selection of an appropriate site (Illustration 8.1). US guidance can be used for nearly any peripheral vein. Most commonly, it is used to access the deep veins of the upper arm.[10] The cephalic vein, which runs laterally, is the most superficial and has no accompanying arteries or nerves. The basilic vein, which runs medially, may be preferable due to its larger size. The brachial veins can also be accessed, though they are generally smaller, deeper, and course adjacent to the brachial artery and median nerve. In general, success rates are best in larger veins less than 1.5 cm from the skin surface.[^12,13] US guidance can also be helpful to facilitate cannulation of superficial veins in the antecubital fossa or forearm. It should be noted that, at least with blind technique, a higher complication rate has been observed for IVs in the hand and forearm.[^14]

Illustration 8.1 Cross-Sectional Upper Arm Anatomy

II08_ArmCrossSectionCartoon.jpg400

Preparation

Once an appropriate site is chosen, the US machine, patient, and operator should be positioned to optimize success (further discussion in the Pitfalls and Challenges section). The probe should be cleaned with an antiseptic cloth and sterile lubricant should be applied. Sterile water is also an option. It is not necessary to cover the probe with a transparent dressing.[^15] The probe should be held with the non-dominant hand. Depth should be adjusted so that the vessel is in the center of the image, and gain should be adjusted so that the lumen of the vessel is black Movie 8.1.

Universal precautions, including hand washing and glove use, should be carried out prior to starting. A luer lock adapter should be attached to a saline flush and filled with saline so it is ready to attach once the needle is removed. A tourniquet should be applied proximal to the selected IV site. The skin just distal to the probe should be prepared with an antiseptic swab. An adhesive dressing should be within arm’s reach so that the IV can be immediately secured once it is in place.

There are two ways to guide peripheral IV insertion with ultrasound: longitudinal and transverse Images 8.2, 8.3. The most common procedure is detailed here, though other approaches have been described, including the use of a modified Seldinger technique.[^16]

Movie 8.1 Optimizing the Image by Adjusting Gain
Image 8.2 Transverse Technique

II08_ShortTechnique.jpg400

Image 8.3 Longitudinal Technique

II08_LongTechnique.jpg400

8.3 Technique

Highlights

  • The transverse or longitudinal technique may be used.
  • Follow the needle tip by fanning the probe.
  • Visualization of the needle tip is of paramount importance.
  • Insert the needle at a 15-45 degree angle. The angle will depend on the depth of the vein.
  • Confirm placement with visualization of vein as saline is flushed.

Transverse Technique

In this technique, the vein is visualized in axial cross section so that it appears on the screen as a circle. Veins will be thin-walled and easily compressible, while arteries will be thick-walled and non-compressible. The needle will appear as a small, bright dot on the screen with dark shadowing or bright repeating artifact. The ultrasound probe should face the same direction as the indicator on the screen so that movement of the needle from medial to lateral in the patient’s arm happens in the same direction on the US machine monitor Movie 8.2.

The needle should be inserted just distal to the ultrasound probe. It should be inserted at a 30 to 45 degree angle and adjusted as needed to advance quickly toward the vessel Movie 8.3.

Movie 8.2 Vein Compression
Movie 8.3 Transverse Technique

As the needle tip moves more proximally, the operator will need to follow it by slowly sweeping the probe proximally Movie 8.4. If the probe is left stationary, the view on the screen will indicate the position of the shaft of the needle, not the tip, leaving the operator to falsely believe the needle tip is still distal and superficial to the vein Illustration 8.2. It is possible to improve your visualization of the needle by making subtle bouncing movements and slowly tilting or fanning the ultrasound probe back and forth until the needle tip is identified.

Movie 8.4 Follow the Tip
Illustration 8.2 Risk of Using Short Axis View

II08_RiskwShortView.jpg400

Longitudinal Technique

In this technique, the vein is visualized in sagittal cross section so that it appears on the screen as a long tube. The leading edge of the probe is placed on the patient’s skin so that it faces toward the hand. This way, when the needle is inserted, it enters at the leading edge and progresses deeper toward the receding edge.

The needle should be inserted directly in front of the probe’s leading edge and can be directed at any angle (generally 15-30 degrees) toward the vein. As long as the probe and needle are exactly aligned, the needle will immediately appear at the leading edge of the screen and will be visible along its entire course into the vessel Movie 8.5.

Movie 8.5 Longitudinal Technique

Comparison of Techniques

Generally, the transverse technique is the one most easily learned by new operators.[^17][^18] It allows for better correction of needle position from medial to lateral and can be ideal when trying to avoid neighboring structures, such as arteries or nerves. It is also generally preferable in uncooperative patients or in critical situations where alignment of the probe, vein, and needle becomes exceedingly difficult. Of course, the main pitfall of the transverse technique is determining the depth of the needle.

For this reason, more experienced operators often prefer to use the longitudinal technique. Though it is more difficult to align the needle, probe, and vein (the width of the ultrasound beam is only 1mm), this technique allows for much better visualization of the needle along its entire course and can confirm that the needle tip and catheter tip are both within the vessel lumen prior to casting off the catheter.[^19] When the catheter is cast off, it can be watched on the screen to confirm that it remains in the lumen. One must take care when cannulating a vein next to an artery using this technique. It is easy to inadvertently slide from one vessel to the other without realizing the error.

Some operators prefer to start the procedure in the transverse view and, once a flash of blood is obtained, rotate the probe to a longitudinal view to confirm that the needle and catheter are in the vessel lumen and watch as the catheter is cast off. To rotate from transverse to longitudinal, keep the vessel in the middle of the screen while slowly rotating 90 degrees to the longitudinal axis Movie 8.6.

Movie 8.6 Rotation from Transverse to Longitudinal
View a demonstration of peripheral IV placement here [[#Movie 8.7 One Minute Ultrasound PIV Demo|Movie 8.7.
Movie 8.7 One Minute Ultrasound PIV Demo

Completing the Procedure

Once a flash is seen in the chamber of the IV, the rest of the procedure should progress similarly to blind technique. Generally, the angle of incidence should be dropped to about 15 degrees and the needle advanced another 1-2mm to ensure that both the tip of the needle and the tip of the catheter are both inside the lumen of the vein. As previously discussed, ultrasound can again be used at this point to confirm that the needle is within the lumen.

The needle should be held in place as the catheter is cast off and completely advanced Movie 8.8. Once the catheter has been cast off, it should not be retracted back onto the needle for fear of shearing off part of the catheter into the vein. The needle should immediately be placed in a sharps container.

Movie 8.8 Casting off Catheter

Blood can be drawn at this point, if needed. Thereafter, the tourniquet should be removed. Pressure can be applied with a finger proximal to the end of the catheter so that blood does not ooze out after the needle is removed. The luer lock adapter can be secured to the catheter. It should be possible to not only draw blood back into the IV tubing but also flush saline into the vein without resistance. If resistance is encountered, or if the patient experiences pain with the flush, the catheter is likely outside of the vessel lumen and should be removed.

Visualization of tiny bubbles within the vessel during saline flush can provide confirmation of intraluminal placement Movie 8.9. Visualization of anechoic fluid in the soft tissue can confirm extraluminal placement and infiltration Movie 8.10.

Movie 8.9 Confirming Placement Using Saline Flush
Movie 8.10 Anechoic Fluid in the Soft Tissue Representing Infiltration

8.4 Pitfalls and Challenges

Highlights

  • Complications are the same as with blind IVs; therefore, providers must still recognize these.
  • Confirm needle tip is in the vessel before casting off catheter.
  • You must use a longer IV catheter due to the depth of these veins.
  • Take the time to properly position the patient and machine. It will save you time in the end.

Common pitfalls specific to the transverse and longitudinal techniques have been previously discussed. Occurrence of infection, phlebitis, thrombosis, and hematoma with ultrasound-guided IVs has not been directly compared to landmark-guided IVs. However, in a selection of ICU patients who had failed multiple blind IV attempts requiring ultrasound-guided IVs, rates of infiltration and phlebitis were significantly lower than in a separate study of general inpatients in whom blind IVs were successfully placed.5,20 Nonetheless, there are some unique considerations with ultrasound-guided deep vein cannulation.
 

Extraluminal Placement

When a peripheral vein is cannulated, the needle often pushes on the superficial wall of the vein, collapsing it onto the deep wall before penetrating through the wall. When enough pressure is applied to penetrate the superficial wall, the needle often passes immediately through the deep wall, leading to a brief flash of blood, but ultimately results in extraluminal placement of the needle tip.

In the blind technique, the usual recommendation is to advance the needle 1-2mm after a flash is seen. However, if the needle has already passed through the deep wall of the vessel, it may actually need to be retracted a few millimeters to re-enter the lumen. Using ultrasound (ideally in the longitudinal view), the operator can confirm the position of the needle tip after the flash and determine whether to advance or retract to ensure intraluminal placement.

Dislodgement & Infiltration

A common pitfall with deep vein cannulation occurs after the IV is secured and the patient begins to move his or her arm. If a standard 1.25-inch catheter is used in a deep vein, the catheter tip will likely become dislodged. Dislodgment is less of a concern when cannulating superficial vessels. However, when an IV is placed deeper in the arm, dislodgment is not only more likely but is often missed until a large amount of fluid has infiltrated Movie 8.11.

Movie 8.11 Infiltrated Soft Tissue
For this reason, a 1.75-inch or, ideally, a 2.5-inch catheter is strongly recommended instead of a 1.5-inch catheter, especially if extravasation of the infused fluid may be harmful (i.e., IV contrast dye or vasopressors) Illustration 8.3. If an even longer line is needed, the IV catheter can be exchanged over a guide wire for an arterial line or a pediatric central line. ##### Illustration 8.3 Non-Ideal vs Ideal Catheter Size ![II08_CatheterSizing.jpg\|400](/img/user/Images/II08_CatheterSizing.jpg)

Because of the depth of veins commonly accessed by US, a standard IV catheter could easily become dislodged

Ergonomic Challenges

First time operators are often challenged by the hand-eye coordination required to match probe and hand movement while balancing visualization of the US screen and the IV. Taking care to position one’s self, the ultrasound, and the patient can reduce or eliminate many of these challenges Gallery 8.1.

[[II08_PositioningArm.jpg]]| Arm positioning 
[[II08_PositioningArm2.jpg]]| Positioning 
[[II08_PositioningRoom.jpg]]| Good positioning 
[[II08_PositioningPoor.jpg]]| Smooth operator...but unsmooth positioning.

Ideally, the patient should be supine with the shoulder slightly abducted, the elbow completely extended, and the forearm completely supinated. Towel rolls can be placed under the elbow to support the arm in this position. The operator should sit facing the head of the bed. The machine should be placed next to the patient’s head, with the screen adjacent to the patient’s arm. Alternatively, the machine may be placed on the opposite side of the bed.

The goal is to turn one’s neck as little as possible. The eyes should be able to move back and forth easily from the screen to the needle. The bed should be raised so that the arm remains completely extended for the procedure. A second operator can help to hold the arm in this position if the patient is moving or uncooperative. Once the needle enters the arm, eyes should remain on the ultrasound screen until it is believed that the needle is in the vessel. The second operator can watch the IV chamber for a flash, or the primary operator can periodically check the chamber as the needle is advanced.

Conclusion

Ultrasound-guided peripheral IV placement is an invaluable tool for physicians and nurses in the emergency department and beyond. Even in the most difficult of patients, an ultrasound-guided IV can usually be placed in a few minutes, allowing critical medications and fluids to be administered. Ultrasound for procedural guidance is a core part of the 2008 ACEP Emergency Ultrasound Guidelines as well as the 2008 CORD Consensus Guidelines on Residency Training in Emergency Ultrasound. All emergency physicians should be proficient at placing ultrasound-guided IVs.

8.5 References


  1. Brannam L, Blaivas M, Lyon M, Flake M. Emergency nurses utilization of ultrasound guidance for placement of peripheral intravenous lines in difficult-access patients. Acad Emerg Med. 2004;11(12):1361-1363. ↩︎

  2. Jones S, Nespert P, Alcoaloumre E. Prehospital intravenous line placement: a prospective study. Ann Emerg Med. 1989;18: 244-246. ↩︎

  3. Constantino T, Parikh A, Satz W, Fojtik J.Ultrasonography-guided peripheral intravenous access versus traditional approaches in patients with difficult intravenous access. Ann Emerg Med. 2005; 46(5):456-461. ↩︎ ↩︎ ↩︎

  4. Bauman M, Braude D, Crandall C. Ultrasound-guidance vs. standard technique in difficult vascular access patients by ED technicians. Amer J Emerg Med. 2009;27:135-140. ↩︎

  5. Gregg S, Murthi S, Sisley A, Stein D, Scalea T. Ultrasound-guided peripheral intravenous acces in the intensive care unit. J Crit Care. 2009(3):514-519. ↩︎

  6. Keyes L, Frazee B, Snoey E, Simon B, Christy D. Ultrasound-fuided brachial and basilic vein cannulation in emergency department patients with difficult intravenous access. Ann Emerg Med. 1999;34(6):711-714. ↩︎

  7. Doniger S, Ishimine P, Fox J, Kanegaye J. Randomized controlled trial of ultrasound-guided peripheral intravenous catheter placement versus traditional techniques in difficult-access pediatric patients. Pediatr Emer Care. 2009;25:154-159. ↩︎

  8. Constantino T, Kirtz J, Satz W. Ultrasound-guided peripheral venous access vs. the external jugular vein as the initial approach to the patient with difficult vascular access. J Emerg Med. 2010;39(4):462-467. ↩︎

  9. American College of Emergency Physicians. (ACEP). Emergency Ultrasound Guidelines – 2008. ACEP Policy Statement. October 2008. Available at: http://www.acep.org/Clinical---Practice-Management/Ultrasound/ ↩︎

  10. Sandhu N, Sidhu D. Mid-arm approach to basilic and cephalic vein cannulation using ultrasound guidance. Brit J Anaesth. 2004;93(2):292-294. ↩︎